Strommasten_Fotolia_122025064_XXL_lichtpunkt_bearb_web

FULLY CERTIFIED TO DELIVER YOUR ENERGY SAFELY INTO THE GRID 

YOUR BENEFITS – STRAIGHTFORWARD. SECURE. ON BUDGET

  • Fulfil NGESO measurement accuracy requirements ≤ 1 mHZ:
    Bachmann‘s GMP232/x is fully certified to ensure no deviations from the required grid frequency range. 
     
  • Highly accurate voltage and current measurement:
    Not only do we deliver best in class frequency measurement, our voltage and current measurement is also extremely accurate. 
     
  • Effortless value acquisition: 
    As a fully integrated system, the GMP232/x cannot be beaten when it comes to installation and commissioning. 
     
  • Exceptional price/performance ratio with maximum flexibility: 
    The GMP232/x has everything it takes to meet NGESO requirements, including real-time network event analysis and rapid fault detection. 
Signet_GMP_simply_precise

A Challenge for many, Business as Usual for us

Frequency deviation under 1 mHz is nothing new for Bachmann

The newest statutory frequency range regulations from the National Grid ESO‘s new Dynamic Containment (DC) service place an extremely high demand on grid measuring devices. 

As pioneers in the energy field for many years, Bachmann has long fulfilled these requirements with our controller-integrated solution; the GMP232/x.

mx207_gmp232_fokus_gmp_var2

AVAILABILITY THROUGH QUALITY

In-house production
48-hour run-in testing
100% series testing
High temperature exposure
icon_high_voltage_rgb
Grid Measurement GMP232/x
  • Accuracy frequency: 0.001 Hz 
  • Accuracy current and voltage: 0.1%
  • Measurement interval (rms value update rate)
    Frequency: 1,66ms
    Current and voltage: 1ms
icon_07_flexibilitaet_rgb
Controller Functions
  • Data logging of local and external values within 50ms 
  • CSV files generated according to the NGESO‘s Performance Monitoring CSV-File Format specification
  • Customer-specific functionality in IEC 61131, C/C++ 
icon_33_unendlich_viele_engineering_umgebungen_rgb
Certification
  • ENA G99 Issue 1 Amendment 4, June 2019 (UK) 
  • VDE-AR-N 4110:2018, FGW TR3 (Rev. 25), FGW TR8 (Rev. 9) (GER) 
  • IEEE C37.90:2005 (USA)
icon_18_geruestet_fuer_die_zukunft_rgb
Time Synchronisation
  • SNTP 
  • PTP/IEEE 1588 
icon_35_bewaehrte_loesung_rgb
Security
  • Layer-based protection concept 
  • Ethernet load limitation 
  • Network services and protocols secured through authentication and end-to-end encryption (SSL/TLS)
  • Access control and access logging 
  • Protective functions at system level 
  • Predefined security levels for basic protection
icon_47_interoperabilitaet_rgb
Communication and Protocols
  • IEC60870-5-101/103/104
  • IEC61850 Client and Server (MMS, Goose, Sampled Values)
  • IEC61400-25 Client and Server
  • DNP3 Master and Outstation
  • Modbus TCP/RTU
  • Profibus DP
  • Profinet
  • OPC UA Server/Client
  • MQTT
  • RS232/422/485
  • FTP/FTPS
  • NFS
  • SNMP
  • Email
  • Web visualisation

Above and Beyond the Standard Requirements

Autonomous measurement, real-time detection

Minimal configuration for flexible, precise power measurement

Each GMP232/x module requires a Bachmann controller system. The recommended minimum requirement is our MX207 controller combined with the GMP232/x. This combination not only fufils statutory measurement requirements; it also offers many other useful functions and advantages for power generation plant operators. 

Expandable, decentralised measurement configuration 

  • Complete network acquisition & monitoring setup with GMP232/x
  • Modular software design allows additional applications
  • Expandable with display devices
  • Visualisation server runs directly on CPU
  • Dynamic data display compatible with any web browser, PC, tablet, smartphone
  • Special industrial operator panels 7 - 21“
  • Comprehensive visualisation software suite M1 webMIpro
  • Expandable with I/O & fieldbus modules
  • Modular controller system allows comprehensive expansion
  • Up to 16 modules per station (minimum set plus 12)
GMP_Composing_erweiterbar

Basic Package

MX207 plus GMP232/x controller, appropriate backplane, connector and terminal set. 

mx207_gmp232_perspektivisch_wenigerverzerrt_schatten

Measurement Accuracy - Better than 1 mHz